Skip to content
PDF

Troubleshooting

This chapter collects situations that can surprise you, and what to do about them. It grows with the manual: each area of the realignment adds its own.

Starting BIMopen

The web app shows «BIMopen non si è avviato» and an error

The browser could not give BIMopen a graphics surface: the message ends with webgl2 not available or with a WebGPU error. BIMopen in the browser needs WebGPU or WebGL2.

  • Turn on hardware acceleration in the settings of the browser, then reload the page.
  • Try another browser, or a newer version of the same one.
  • Add ?webgl to the address to use WebGL2 even where WebGPU exists but does not work.

The desktop app does not build on Linux

The interface needs the development files of xkbcommon, Wayland and GTK 3. On Debian and Ubuntu:

sudo apt-get install -y libxkbcommon-dev libwayland-dev libgtk-3-dev

The interface

The element panel or the Project Index has disappeared

Views ▸ Windows ▸ Panels shows or hides them: tick them again there. The Properties tile of the contextual card also shows the element panel again. A click on the rail entry already chosen folds the tool panel: click it again to open it.

What I type ends up at the command line

Whatever you type while no field is being edited goes to the command line, the search box of the top bar: this is how typed shortcuts work. To type in a field of the element panel or of a dialog, click the field first.

A tile is greyed

Some tools work only in the right view, and their tip says why. Area Outline and Area need an open area plan: the tip says Open an area plan first. Save View needs an open 3D view; Document ▸ Sheets ▸ View needs an open sheet; Undo and Redo are greyed when there is nothing to undo or redo.

DL starts a dimension instead of a detail line

DL is the short form of the linear dimension. To draw detail lines, use Document ▸ Detail ▸ Detail line, or type detailline.

Modelling

«no wall at that point»

A door or a window must be placed in a wall. Click on the wall itself, or give a point on its line at the command line.

A height set at the command line is enormous

At the command line a number without unit is in metres: set Free Height 2700 makes the wall 2700 m high. Undo with Ctrl+Z and write the unit: 2700mm or 2.7m. In the element panel a number without unit is in the project's units.

Files

Unsaved work is gone after New, Open or Sample project

These commands replace the current project without asking. Save before using them: the asterisk Unsaved changes in the top bar shows that there are changes to save.

Open… in the browser does not show a file dialog

In the browser, drag the .bpr file into the page: the command line says Drag a .bpr file into the window to open it.

bimopen-cli prints its usage and stops

The arguments are not the ones it expects: it ends with code 2 and shows the usage. A command that fails ends with code 1 and a message saying which line failed. See Command line and MCP.